Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485244

RESUMO

BACKGROUND: Postacute Covid-19 patients commonly present with respiratory symptoms; however, a noninvasive imaging method for quantitative characterization of respiratory patterns is lacking. PURPOSE: To evaluate if quantitative characterization of respiratory pattern on free-breathing higher temporal resolution MRI stratifies patients by cardiopulmonary symptom burden. STUDY TYPE: Prospective analysis of retrospectively acquired data. SUBJECTS: A total of 37 postacute Covid-19 patients (25 male; median [interquartile range (IQR)] age: 58 [42-64] years; median [IQR] days from acute infection: 335 [186-449]). FIELD STRENGTH/SEQUENCE: 0.55 T/two-dimensional coronal true fast imaging with steady-state free precession (trueFISP) at higher temporal resolution. ASSESSMENT: Patients were stratified into three groups based on presence of no (N = 11), 1 (N = 14), or ≥2 (N = 14) cardiopulmonary symptoms, assessed using a standardized symptom inventory within 1 month of MRI. An automated lung postprocessing workflow segmented each lung in each trueFISP image (temporal resolution 0.2 seconds) and respiratory curves were generated. Quantitative parameters were derived including tidal lung area, rates of inspiration and expiration, lung area coefficient of variability (CV), and respiratory incoherence (departure from sinusoidal pattern) were. Pulmonary function tests were recorded if within 1 month of MRI. Qualitative assessment of respiratory pattern and lung opacity was performed by three independent readers with 6, 9, and 23 years of experience. STATISTICAL TESTS: Analysis of variance to assess differences in demographic, clinical, and quantitative MRI parameters among groups; univariable analysis and multinomial logistic regression modeling to determine features predictive of patient symptom status; Akaike information criterion to compare the quality of regression models; Cohen and Fleiss kappa (κ) to quantify inter-reader reliability. Two-sided 5% significance level was used. RESULTS: Tidal area and lung area CV were significantly higher in patients with two or more symptoms than in those with one or no symptoms (area: 15.4 cm2 vs. 12.9 cm2 vs. 12.8 cm2 ; CV: 0.072, 0.067, and 0.058). Respiratory incoherence was significantly higher in patients with two or more symptoms than in those with one or no symptoms (0.05 vs. 0.043 vs. 0.033). There were no significant differences in patient age (P = 0.19), sex (P = 0.88), lung opacity severity (P = 0.48), or pulmonary function tests (P = 0.35-0.97) among groups. Qualitative reader assessment did not distinguish between groups and showed slight inter-reader agreement (κ = 0.05-0.11). DATA CONCLUSION: Quantitative respiratory pattern measures derived from dynamic higher-temporal resolution MRI have potential to stratify patients by symptom burden in a postacute Covid-19 cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
Invest Radiol ; 58(10): 720-729, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37222526

RESUMO

INTRODUCTION: Prostate cancer diffusion weighted imaging (DWI) MRI is typically performed at high-field strength (3.0 T) in order to overcome low signal-to-noise ratio (SNR). In this study, we demonstrate the feasibility of prostate DWI at low field enabled by random matrix theory (RMT)-based denoising, relying on the MP-PCA algorithm applied during image reconstruction from multiple coils. METHODS: Twenty-one volunteers and 2 prostate cancer patients were imaged with a 6-channel pelvic surface array coil and an 18-channel spine array on a prototype 0.55 T system created by ramping down a commercial magnetic resonance imaging system (1.5 T MAGNETOM Aera Siemens Healthcare) with 45 mT/m gradients and 200 T/m/s slew rate. Diffusion-weighted images were acquired with 4 non-collinear directions, for which b = 50 s/mm 2 was used with 8 averages and b = 1000 s/mm 2 with 40 averages; 2 extra b = 50 s/mm 2 were used as part of the dynamic field correction. Standard and RMT-based reconstructions were applied on DWI over different ranges of averages. Accuracy/precision was evaluated using the apparent diffusion coefficient (ADC), and image quality was evaluated over 5 separate reconstructions by 3 radiologists with a 5-point Likert scale. For the 2 patients, we compare image quality and lesion visibility of the RMT reconstruction versus the standard one on 0.55 T and on clinical 3.0 T. RESULTS: The RMT-based reconstruction in this study reduces the noise floor by a factor of 5.8, thereby alleviating the bias on prostate ADC. Moreover, the precision of the ADC in prostate tissue after RMT increases over a range of 30%-130%, with the increase in both signal-to-noise ratio and precision being more prominent for a low number of averages. Raters found that the images were consistently of moderate to good overall quality (3-4 on the Likert scale). Moreover, they determined that b = 1000 s/mm 2 images from a 1:55-minute scan with the RMT-based reconstruction were on par with the corresponding images from a 14:20-minute scan with standard reconstruction. Prostate cancer was visible on ADC and calculated b = 1500 images even with the abbreviated 1:55-minute scan reconstructed with RMT. CONCLUSIONS: Prostate imaging using DWI is feasible at low field and can be performed more rapidly with noninferior image quality compared with standard reconstruction.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Estudos de Viabilidade , Neoplasias da Próstata/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Razão Sinal-Ruído , Reprodutibilidade dos Testes
3.
Otol Neurotol ; 44(4): e223-e229, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36806625

RESUMO

OBJECTIVE: To determine if metal reduction magnetic resonance imaging sequences and changes in implant placement minimize artifact from cochlear implants and improve visualization of intracranial structures. STUDY DESIGN: Cadaveric study. SETTING: Tertiary referral center. PATIENTS: Five cadaveric heads. INTERVENTIONS: Specimens were implanted with Advanced Bionics HiRes Ultra3D devices at nasion-external auditory canal angles of 90, 120, and 160 degrees, and distances from the external auditory canal of 9 or 12 cm. Standard brain/internal auditory canal (IAC) sequences with metal artifact reducing technique were acquired in a 1.5T scanner. MAIN OUTCOME MEASURES: The primary outcome was visibility of 14 intracranial structures graded on a 4-point scale (1, structures <50% visible; 2, >50% visible with some areas nonvisible from artifact; 3, artifact present but adequate for diagnosis; and 4, high quality). Scores were determined by experienced head and neck radiologists and compared with one-way analysis of variance. RESULTS: Imaging sequences included axial 5-mm whole-brain turbo spin echo (TSE) T2 with right to left and anterior to posterior encoding, fluid-attenuation inversion recovery high bandwidth, axial 5-mm whole-brain slice-encoding metal artifact correction (SEMAC), axial IAC constructive interference in steady state, and axial 3-mm T1 IAC with and without fat saturation. T1 IACs in axial and coronal planes were best for ipsilateral structures overall (mean [standard deviation {SD}], 3.8 [0.6] and 3.8 [0.5]). SEMAC (mean [SD], 3.5 [0.8]) was superior to TSE with anterior to posterior encoding (mean [SD], 3.5 [0.9) for ipsilateral cortex, cerebellopontine angle, and brainstem/cerebellum, and equivalent for the inner ear. Constructive interference in steady state and T1 with fat saturation were poor for all ipsilateral structures (mean, 2.8 [ p < 0.01]; mean, 3.1 [ p < 0.01]). The 120 degrees/12 cm position was overall best, although the 120 degrees/9 cm position still afforded visualization of ipsilateral structures; other angles and distances conferred slight advantages for specific structures of interest. CONCLUSIONS: SEMAC and T2 TSE with anterior to posterior encoding sequences provide artifact suppression while retaining excellent image quality. Different placement angles did not confer improvement in visualization, although placement distances provided slight advantages for some structures.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Artefatos , Imãs , Imageamento por Ressonância Magnética/métodos , Cadáver
4.
Sci Rep ; 12(1): 15010, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36056131

RESUMO

Flexible radiofrequency coils for magnetic resonance imaging (MRI) have garnered attention in research and industrial communities because they provide improved accessibility and performance and can accommodate a range of anatomic postures. Most recent flexible coil developments involve customized conductors or substrate materials and/or target applications at 3 T or above. In contrast, we set out to design a flexible coil based on an off-the-shelf conductor that is suitable for operation at 0.55 T (23.55 MHz). Signal-to-noise ratio (SNR) degradation can occur in such an environment because the resistance of the coil conductor can be significant with respect to the sample. We found that resonating a commercially available RG-223 coaxial cable shield with a lumped capacitor while the inner conductor remained electrically floating gave rise to a highly effective "cable coil." A 10-cm diameter cable coil was flexible enough to wrap around the knee, an application that can benefit from flexible coils, and had similar conductor loss and SNR as a standard-of-reference rigid copper coil. A two-channel cable coil array also provided good SNR robustness against geometric variability, outperforming a two-channel coaxial coil array by 26 and 16% when the elements were overlapped by 20-40% or gapped by 30-50%, respectively. A 6-channel cable coil array was constructed for 0.55 T knee imaging. Incidental cartilage and bone pathologies were clearly delineated in T1- and T2-weighted turbo spin echo images acquired in 3-4 min with the proposed coil, suggesting that clinical quality knee imaging is feasible in an acceptable examination timeframe. Correcting for T1, the SNR measured with the cable coil was approximately threefold lower than that measured with a 1.5 T state-of-the-art 18-channel coil, which is expected given the threefold difference in main magnetic field strength. This result suggests that the 0.55 T cable coil conductor loss does not deleteriously impact SNR, which might be anticipated at low field.


Assuntos
Articulação do Joelho , Imageamento por Ressonância Magnética , Desenho de Equipamento , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
5.
Eur J Radiol ; 156: 110515, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36099832

RESUMO

PURPOSE: To evaluate detection and characterization of groundglass and fibrosis-like opacities imaged by non-contrast 0.55 Tesla MRI, and versus clinically-acquired chest CT images, in a cohort of post-Covid patients. MATERIALS AND METHODS: 64 individuals (26 women, mean age 53 ± 14 years, range 19-85) with history of Covid-19 pneumonia were recruited through a survivorship registry, with 106 non-contrast low-field 0.55 T cardiopulmonary MRI exams acquired from 9/8/2020-9/28/2021. MRI exams were obtained at an average interval of 9.5 ± 4.5 months from initial symptom report (range 1-18 months). Of these, 20 participants with 22 MRI exams had corresponding clinically-acquired CT chest imaging obtained within 30 days of MRI (average interval 18 ± 9 days, range 0-30). MR and CT images were reviewed and scored by two thoracic radiologists, for presence and extent of lung opacity by quadrant, opacity distribution, and presence versus absence of fibrosis-like subpleural reticulation and subpleural lines. Scoring was performed for each of four lung quadrants: right upper and middle lobe, right lower lobe, left upper lobe and lingula, and left lower lobe. Agreement between readers and modalities was assessed with simple and linear weighted Cohen's kappa (k) coefficients. RESULTS: Inter-reader concordance on CT for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 99%, 78%, 97%, 99%, and 94% (k 0.96, 0.86, 0.94, 0.97, 0.89), respectively. Inter-reader concordance on MR, among all 106 exams, for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 85%, 48%, 70%, 86%, and 76% (k 0.57, 0.32, 0.46, 0.47, 0.37), respectively. Inter-modality agreement between CT and MRI for opacity presence, opacity extent, opacity distribution, and presence subpleural lines and reticulation was 86%, 52%, 79%, 93%, and 76% (k 0.43, 0.63, 0.65, 0.80, 0.52). CONCLUSION: Low-field 0.55 T non-contrast MRI demonstrates fair to moderate inter-reader concordance, and moderate to substantial inter-modality agreement with CT, for detection and characterization of groundglass and fibrosis-like opacities.


Assuntos
COVID-19 , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Fibrose
6.
Invest Radiol ; 57(8): 517-526, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35239614

RESUMO

OBJECTIVES: Despite significant progress, artifact-free visualization of the bone and soft tissues around hip arthroplasty implants remains an unmet clinical need. New-generation low-field magnetic resonance imaging (MRI) systems now include slice encoding for metal artifact correction (SEMAC), which may result in smaller metallic artifacts and better image quality than standard-of-care 1.5 T MRI. This study aims to assess the feasibility of SEMAC on a new-generation 0.55 T system, optimize the pulse protocol parameters, and compare the results with those of a standard-of-care 1.5 T MRI. MATERIALS AND METHODS: Titanium (Ti) and cobalt-chromium total hip arthroplasty implants embedded in a tissue-mimicking American Society for Testing and Materials gel phantom were evaluated using turbo spin echo, view angle tilting (VAT), and combined VAT and SEMAC (VAT + SEMAC) pulse sequences. To refine an MRI protocol at 0.55 T, the type of metal artifact reduction techniques and the effect of various pulse sequence parameters on metal artifacts were assessed through qualitative ranking of the images by 3 expert readers while taking measured spatial resolution, signal-to-noise ratios, and acquisition times into consideration. Signal-to-noise ratio efficiency and artifact size of the optimized 0.55 T protocols were compared with the 1.5 T standard and compressed-sensing SEMAC sequences. RESULTS: Overall, the VAT + SEMAC sequence with at least 6 SEMAC encoding steps for Ti and 9 for cobalt-chromium implants was ranked higher than other sequences for metal reduction ( P < 0.05). Additional SEMAC encoding partitions did not result in further metal artifact reductions. Permitting minimal residual artifacts, low magnetic susceptibility Ti constructs may be sufficiently imaged with optimized turbo spin echo sequences obviating the need for SEMAC. In cross-platform comparison, 0.55 T acquisitions using the optimized protocols are associated with 45% to 64% smaller artifacts than 1.5 T VAT + SEMAC and VAT + compressed-sensing/SEMAC protocols at the expense of a 17% to 28% reduction in signal-to-noise ratio efficiency. B 1 -related artifacts are invariably smaller at 0.55 T than 1.5 T; however, artifacts related to B 0 distortion, although frequently smaller, may appear as signal pileups at 0.55 T. CONCLUSIONS: Our results suggest that new-generation low-field SEMAC MRI reduces metal artifacts around hip arthroplasty implants to better advantage than current 1.5 T MRI standard of care. While the appearance of B 0 -related artifacts changes, reduction in B 1 -related artifacts plays a major role in the overall benefit of 0.55 T.


Assuntos
Artroplastia de Quadril , Artefatos , Cromo , Cobalto , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Titânio
7.
Clin Imaging ; 83: 177-183, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35092926

RESUMO

OBJECTIVE: Texture features are proposed for classification and prognostication, with lacking information about variability. We assessed 3 T liver MRI feature variability. METHODS: Five volunteers underwent standard 3 T MRI, and repeated with identical and altered parameters. Two readers placed regions of interest using 3DSlicer. Repeatability (between standard and repeat scan), robustness (between standard and parameter changed scan), and reproducibility (two reader variation) were computed using coefficient of variation (CV). RESULTS: 67%, 49%, and 61% of features had good-to-excellent (CV ≤ 10%) repeatability on ADC, T1, and T2, respectively, least frequently for first order (19-35%). 22%, 19%, and 21% of features had good-to-excellent robustness on ADC, T1, and T2, respectively. 52%, 35%, and 25% of feature measurements had good-to-excellent inter-reader reproducibility on ADC, T1, and T2, respectively, with highest good-to-excellent reproducibility for first order features on ADC/T1. CONCLUSION: We demonstrated large variations in texture features on 3 T liver MRI. Further study should evaluate methods to reduce variability.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
8.
Abdom Radiol (NY) ; 46(12): 5772-5780, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34415411

RESUMO

PURPOSE: To develop a protocol for abdominal imaging on a prototype 0.55 T scanner and to benchmark the image quality against conventional 1.5 T exam. METHODS: In this prospective IRB-approved HIPAA-compliant study, 10 healthy volunteers were recruited and imaged. A commercial MRI system was modified to operate at 0.55 T (LF) with two different gradient performance levels. Each subject underwent non-contrast abdominal examinations on the 0.55 T scanner utilizing higher gradients (LF-High), lower adjusted gradients (LF-Adjusted), and a conventional 1.5 T scanner. The following pulse sequences were optimized: fat-saturated T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and Dixon T1-weighted imaging (T1WI). Three readers independently evaluated image quality in a blinded fashion on a 5-point Likert scale, with a score of 1 being non-diagnostic and 5 being excellent. An exact paired sample Wilcoxon signed-rank test was used to compare the image quality. RESULTS: Diagnostic image quality (overall image quality score ≥ 3) was achieved at LF in all subjects for T2WI, DWI, and T1WI with no more than one unit lower score than 1.5 T. The mean difference in overall image quality score was not significantly different between LF-High and LF-Adjusted for T2WI (95% CI - 0.44 to 0.44; p = 0.98), DWI (95% CI - 0.43 to 0.36; p = 0.92), and for T1 in- and out-of-phase imaging (95%C I - 0.36 to 0.27; p = 0.91) or T1 fat-sat (water only) images (95% CI - 0.24 to 0.18; p = 1.0). CONCLUSION: Diagnostic abdominal MRI can be performed on a prototype 0.55 T scanner, either with conventional or with reduced gradient performance, within an acquisition time of 10 min or less.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Estudos Prospectivos
9.
Acta Radiol ; 62(1): 58-66, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32233646

RESUMO

BACKGROUND: Half-Fourier acquisition single-shot turbo spin-echo (HASTE), continuous radial gradient-echo (GRE), and True FISP allow real-time dynamic assessment of the spine. PURPOSE: To evaluate the feasibility of adding dynamic sequences to routine spine magnetic resonance imaging (MRI) for assessment of spondylolisthesis. MATERIAL AND METHODS: Retrospective review was performed of patients referred for dynamic MRI of the cervical or lumbar spine between January 2017 and 2018 who had flexion-extension radiographs within two months of MRI. Exclusion criteria were: incomplete imaging; spinal hardware; and inability to tolerate dynamic examination. Blinded, independent review by two board-certified musculoskeletal radiologists was performed to assess for spondylolisthesis (>3 mm translation); consensus review of dynamic radiographs served as the gold standard. Cervical spinal cord effacement was assessed. Inter-reader agreement and radiographic concordance was calculated for each sequence. RESULTS: Twenty-one patients were included (8 men, 13 women; mean age 47.9 ± 16.5 years). Five had MRI of the cervical spine and 16 had MRI of the lumbar spine. Mean acquisition time was 18.4 ± 1.7 min with dynamic sequences in the range of 58-77 s. HASTE and True FISP had the highest inter-reader reproducibility (κ = 0.88). Reproducibility was better for the lumbar spine (κ = 0.94) than the cervical spine (κ = 0.28). Sensitivity of sequences for spondylolisthesis was in the range of 68.8%-78.6%. All three sequences had high accuracy levels: ≥90.5% averaged across the cervical and lumbar spine. Cervical cord effacement was observed during dynamic MRI in two cases (100% agreement). CONCLUSION: Real-time dynamic MRI sequences added to spine MRI protocols provide reliable and accurate assessment of cervical and lumbar spine spondylolisthesis during flexion and extension.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Espondilolistese/diagnóstico por imagem , Espondilolistese/fisiopatologia , Fenômenos Biomecânicos/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
Front Neuroanat ; 14: 9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32265669

RESUMO

OBJECTIVES: Clinically relevant neuroanatomy is challenging to teach, learn and remember since many functionally important structures are visualized best using histology stains from serial 2D planar sections of the brain. In clinical patients, the locations of specific structures then must be inferred from spatial position and surface anatomy. A 3D MRI dataset of neuroanatomy has several advantages including simultaneous multi-planar visualization in the same brain, direct end-user manipulation of the data and image contrast identical to clinical MRI. We created 3D MRI datasets of the postmortem brain with high spatial and contrast resolution for simultaneous multi-planar visualization of complex neuroanatomy. MATERIALS AND METHODS: Whole human brains (N = 6) were immersion-fixed in 4% formaldehyde for 4 weeks, then washed continuously in water for 48 h. The brains were imaged on a clinical 3-T MRI scanner with a 64-channel head and neck coil using a 3D T2-weighted sequence with 400-micron isotropic resolution (voxel = 0.064 mm3; time = 7 h). Besides resolution, this sequence has multiple adjustments to improve contrast compared to a clinical protocol, including 93% reduced turbo factor and 77% reduced effective echo time. RESULTS: This MRI microscopy protocol provided excellent contrast resolution of small nuclei and internal myelinated pathways within the basal ganglia, thalamus, brainstem, and cerebellum. Contrast was sufficient to visualize the presence and variation of horizontal layers in the cerebral cortex. 3D isotropic resolution datasets facilitated simultaneous multi-planar visualization and efficient production of specific tailored oblique image orientations to improve understanding of complex neuroanatomy. CONCLUSION: We created an unlabeled high-resolution digital 3D MRI dataset of neuroanatomy as an online resource for readers to download, manipulate, annotate and use for clinical practice, research, and teaching that is complementary to traditional histology-based atlases. Digital MRI contrast is quantifiable, reproducible across brains and could help validate novel MRI strategies for in vivo structure visualization.

12.
Radiol Artif Intell ; 2(1): e190007, 2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-32076662

RESUMO

A publicly available dataset containing k-space data as well as Digital Imaging and Communications in Medicine image data of knee images for accelerated MR image reconstruction using machine learning is presented.

13.
Oper Neurosurg (Hagerstown) ; 17(5): 525-530, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30892657

RESUMO

BACKGROUND: Intramedullary spinal cord neoplasms (ISCN) pose significant management challenges. Advances in magnetic resonance imaging (MRI) (such as diffusion tensor imaging, DTI) have been utilized to determine the infiltrative nature and resectability of ISCN. However, this has not been applied to intraoperative decision making. OBJECTIVE: To present a case series of 2 patients with ISCN, the first to combine use of DTI, pre- and intraoperative 3-dimensional (3D) virtual reality imaging, and microscope integrated navigation with heads-up display. METHODS: Two patients who underwent surgery for ISCN were included. DTI images were obtained and 3D images were created using Surgical Theater (Surgical Theater SRP, Version 7.4.0, Cleveland, Ohio). Fiducials were used to achieve accurate surface registration to C4. Navigation confirmed the levels of laminectomy necessary. The microscope was integrated with Brainlab (Brainlab AG Version 3.0.5, Feldkirchen, Germany) and the tumor projected in the heads-up display. Surgical Theater was integrated with Brainlab to allow for real time evaluation of the 3D tractography. RESULTS: Case 1: All tracts were pushed away from the tumor, suggesting it was not infiltrative. Surgical Theater and Brainlab assisted in confirming midline despite the abnormal swelling of the cord so the myelotomy could be performed. The heads-up display outline demonstrated excellent correlation to the tumor. Gross total resection was achieved. Diagnosis of ependymoma was confirmed. Case 2: Some tracts were going through the tumor itself, suggesting an infiltrative process. Surgical Theater and Brainlab again allowed for confirmation of the midline raphe. Near total resection of the enhancing portion was achieved. Diagnosis of glioblastoma was confirmed. CONCLUSION: This is a proof of concept application where multi-modal imaging technology was utilized for safest maximal ISCN resection.


Assuntos
Imagem de Tensor de Difusão/métodos , Ependimoma/cirurgia , Glioblastoma/cirurgia , Procedimentos Neurocirúrgicos/métodos , Neoplasias da Medula Espinal/cirurgia , Adulto , Vértebras Cervicais , Tomada de Decisão Clínica , Ependimoma/diagnóstico por imagem , Ependimoma/patologia , Glioblastoma/diagnóstico por imagem , Glioblastoma/patologia , Humanos , Imageamento Tridimensional/métodos , Cuidados Intraoperatórios/métodos , Masculino , Microcirurgia/métodos , Imagem Multimodal , Invasividade Neoplásica , Neuronavegação/métodos , Estudo de Prova de Conceito , Neoplasias da Medula Espinal/diagnóstico por imagem , Neoplasias da Medula Espinal/patologia , Realidade Virtual , Adulto Jovem
14.
Invest Radiol ; 53(12): 742-747, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30020139

RESUMO

BACKGROUND AND PURPOSE: High-resolution T2-weighted sequences are frequently used in magnetic resonance imaging (MRI) studies to assess the cerebellopontine angle and internal auditory canal (IAC) in sensorineural hearing loss patients but have low yield and lengthened examinations. Because image content in the Wavelet domain is sparse, compressed sensing (CS) that uses incoherent undersampling of k-space and iterative reconstruction can accelerate MRI acquisitions. We hypothesized that an accelerated CS T2 Sampling Perfection with Application optimized Contrasts using different flip angle Evolution (SPACE) sequence would produce acceptable diagnostic quality for IAC screening protocols. MATERIAL AND METHODS: Seventy-six patients underwent 3 T MRI using conventional SPACE and a CS T2 SPACE prototype sequence for screening the IACs were identified retrospectively. Unilateral reconstructions for each sequence were separated, then placed into mixed folders for independent, blinded review by 3 neuroradiologists during 2 sessions 4 weeks apart. Radiologists reported if a lesion was present. Motion and visualization of specific structures were rated using ordinal scales. McNemar, Wilcoxon, Cohen κ, and Mann-Whitney U tests were performed for accuracy, equivalence, and interrater and intrarater reliability. RESULTS: T2 SPACE using CS reconstruction reduced scan time by 80% to 50 seconds and provided 98.7% accuracy for IAC mass detection by 3 raters. Radiologists preferred conventional images (0.7-1.0 reduction on 5-point scale, P < 0.001), but rated CS SPACE acceptable. The 95% confidence for reduction in any cerebellopontine angle, IAC, or fluid-filled inner ear structure assessment with CS SPACE did not exceed 0.5. CONCLUSIONS: Internal auditory canal screening MRI protocols can be performed using a 5-fold accelerated T2 SPACE sequence with compressed sensing while preserving diagnostic image quality and acceptable lesion detection rate.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Doenças do Labirinto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Orelha Interna/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Magn Reson Imaging ; 53: 148-155, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30006022

RESUMO

OBJECT: To quantify and compare subregional proximal femur bone marrow fat composition in premenopausal and postmenopausal women using chemical shift-encoded-MRI (CSE-MRI). MATERIALS AND METHODS: A multi gradient-echo sequence at 3 T was used to scan both hips of premenopausal (n = 9) and postmenopausal (n = 18) women. Subregional fat composition (saturation, poly-unsaturation, mono-unsaturation) was quantitatively assessed in the femoral head, femoral neck, Ward's triangle, greater trochanter, and proximal shaft in bone marrow adipose tissue and separately within red and yellow marrow adipose tissue. RESULTS: Significant differences in fat composition in postmenopausal compared to premenopausal women, which varied depending on the subregion analyzed, were found. Within both whole and yellow marrow adipose tissue, postmenopausal women demonstrated higher saturation (+14.7% to +43.3%), lower mono- (-11.4% to -33%) and polyunsaturation (-52 to -83%) (p < 0.05). Within red marrow adipose tissue, postmenopausal women demonstrated lower fat quantity (-16% to -24%) and decreased polyunsaturation (-80 to -120%) in the femoral neck, greater trochanter, and Ward's triangle (p < 0.05). CONCLUSION: CSE-MRI can be used to detect subregional differences in proximal femur marrow adipose tissue composition between pre- and post-menopausal women in clinically feasible scan times.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Densidade Óssea , Feminino , Fêmur/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Projetos Piloto , Pós-Menopausa , Pré-Menopausa
16.
AJR Am J Roentgenol ; 210(6): 1309-1316, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29629794

RESUMO

OBJECTIVE: The purpose of this study was to determine whether adding DWI to conventional MRI of the sacroiliac joints improves the diagnostic performance of MRI readers in the detection of sacroiliitis. MATERIALS AND METHODS: MR images of the sacroiliac joints of 63 patients with lower back pain obtained between January 2016 and December 2016 were analyzed retrospectively. Three readers reviewed the MRI studies for bone marrow edema lesions around the sacroiliac joints as a marker of active sacroiliitis and gave a diagnostic confidence score of 0-4 using MRI without DWI and MRI with DWI in separate sessions. The normalized apparent diffusion coefficient mean (nADCmean) was measured. Clinical and radiologic data using the Assessment of Spondyloarthritis International Society criteria were the reference for the diagnosis of sacroiliitis. Diagnostic performance, confidence scores, and interreader agreement for the MRI methods were compared. The nADCmean values of patients with and those without sacroiliitis were compared. RESULTS: The accuracy, sensitivity, and specificity of MRI without DWI were 68.3%, 69.0%, and 67.6% and for MRI with DWI were 74.6%, 69.0%, and 79.4% (accuracy and sensitivity, p > 0.100; specificity, p = 0.039). The mean confidence score for MRI without DWI was 3.60 and for MRI with DWI was 3.67 (p = 0.270). The kappa coefficient for MRI without DWI was 0.28 and for MRI with DWI was 0.46 (p = 0.041). The nADCmean in patients with sacroiliitis was 3.86 and in patients without sacroiliitis was 1.6 (p ≤ 0.001). The nADCmean AUC was 0.758 (95% CI, 0.67-0.83). CONCLUSION: The addition of DWI to conventional MRI does not significantly improve overall diagnostic performance in terms of accuracy, sensitivity, or confidence in the detection of inflammatory sacroiliitis, but it does have increased specificity and interobserver agreement. ADC threshold values can be used as predictors of sacroiliitis but give no added advantage over MRI with DWI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Sacroileíte/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
J Magn Reson Imaging ; 48(2): 431-440, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29357200

RESUMO

BACKGROUND: There is growing interest in detecting cerebro-cerebellar circuits, which requires adequate blood oxygenation level dependent contrast and signal-to-noise ratio (SNR) throughout the brain. Although 7T scanners offer increased SNR, coverage of commercial head coils is currently limited to the cerebrum. PURPOSE: To improve cerebellar functional MRI (fMRI) at 7T with high permittivity material (HPM) pads extending the sensitivity of a commercial coil. STUDY TYPE: Simulations were used to determine HPM pad configuration and assess radiofrequency (RF) safety. In vivo experiments were performed to evaluate RF field distributions and SNR and assess improvements of cerebellar fMRI. SUBJECTS: Eight healthy volunteers enrolled in a prospective motor fMRI study with and without HPM. FIELD STRENGTH/SEQUENCE: Gradient echo (GRE) echo planar imaging for fMRI, turbo FLASH for flip angle mapping, GRE sequence for SNR maps, and T1 -weighted MPRAGE were acquired with and without HPM pads at 7T. ASSESSMENT: Field maps, SNR maps, and anatomical images were evaluated for coverage. Simulation results were used to assess SAR levels of the experiment. Activation data from fMRI experiments were compared with and without HPM pads. STATISTICAL TESTS: fMRI data were analyzed using FEAT FSL for each subject followed by group level analysis using paired t-test of acquisitions with and without HPM. RESULTS: Simulations showed 52% improvement in transmit efficiency in cerebellum with HPM and SAR levels well below recommended limits. Experiments showed 27% improvement in SNR in cerebellum and improvement in coverage on T1 -weighted images. fMRI showed greater cerebellar activation in individual subjects with the HPM pad present (Z > = 4), especially in inferior slices of cerebellum, with 59% average increase in number of activated voxels in the cerebellum. Group-level analysis showed improved functional activation (Z > = 2.3) in cerebellar regions with HPM pads without loss of measured activation elsewhere. DATA CONCLUSION: HPM pads can improve cerebellar fMRI at 7T with a commonly-used head coil without compromising RF safety. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:431-440.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Simulação por Computador , Meios de Contraste/química , Desenho de Equipamento , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Ondas de Rádio , Reprodutibilidade dos Testes , Razão Sinal-Ruído
18.
J Magn Reson Imaging ; 47(3): 723-728, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28577329

RESUMO

PURPOSE: To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2 -weighted (T2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. MATERIALS AND METHODS: We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. RESULTS: There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). CONCLUSION: We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T2 WI of the liver. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Aprendizado Profundo , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Clin Imaging ; 45: 37-50, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28601735

RESUMO

Diffusion imaging of the spine has the potential to change clinical management, but is challenging due to the small size of the cord and susceptibility artifacts from adjacent structures. Reduced field-of-view (rFOV) diffusion can improve image quality by decreasing the echo train length. Over the past 2 years, we have acquired a rFOV diffusion sequence for MRI spine protocols on most inpatients and emergency room patients. We provide selected imaging diagnoses to illustrate the utility of including diffusion spine MRI in clinical practice. Our experiences support using diffusion MRI to improve diagnostic certainty and facilitate prompt treatment or clinical management.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Serviço Hospitalar de Emergência , Hospitalização , Doenças da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Criança , Protocolos Clínicos , Difusão , Imagem Ecoplanar/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pacientes Internados , Masculino , Pessoa de Meia-Idade , Doenças da Medula Espinal/diagnóstico , Doenças da Medula Espinal/patologia , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/patologia , Coluna Vertebral/patologia , Adulto Jovem
20.
J Neuroophthalmol ; 37(2): 187-196, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28459736

RESUMO

BACKGROUND: Clinical orbital MRI protocols are routinely used to study the optic nerves and exclude compressive lesions, infarctions, or inflammation. However, the small caliber and divergent oblique orientations of the optic nerves make it challenging to characterize them well with conventional MRI, especially since adjacent air-filled bony structures distort the MRI signal and motion is a problem even in cooperative, healthy volunteers. EVIDENCE ACQUISITION: Over the past 3 years we have experimented with multiple novel MRI approaches and sequences to better characterize the optic nerves. The perfect MRI protocol would be quantitative and sensitive to subtle optic nerve pathologic changes, provide high spatial resolution, be rapidly acquired, and resistant to motion degradation. RESULTS: This review provides an update of recent MRI sequence innovations for the optic nerves being currently translated into clinical practice. Methods discussed include rapid MRI with compressed sensing or simultaneous multislice approaches, postprocessing techniques for quantitative T2 mapping or track density imaging, and multiple MRI sequences for measuring diffusion in the optic nerves. CONCLUSIONS: Recently-developed orbit-specific MRI coils, quantitative sequences, and rapid acquisition techniques can improve our future ability to study optic nerve pathologies noninvasively. As advanced MRI becomes more proficient at characterizing the optic nerves, its role in the clinical management of patients should increase.


Assuntos
Imageamento por Ressonância Magnética/métodos , Nervo Óptico/patologia , Neurite Óptica/diagnóstico , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...